1. Product Overview

Our 5m Manual-Electric Integrated Spiral Cable Telescopic Mast, also known as a 5m Electric Telescopic Mast with Spiral Cable, is a versatile lifting solution that combines electric drive, manual backup operation, and an integrated spiral cable system. We designed this mast for emergency response, outdoor equipment installation, and mobile support applications where reliable lifting and continuous power or signal transmission are essential.
The mast features a multi-section telescopic column with a distinctive fire-red polyester powder coating. In addition, its side-mounted spiral spring cable extends and retracts together with the mast, providing convenient power and signal connections for top-mounted equipment without the need for loose external cable management.
Our integrated drive system supports electric operation under normal conditions and manual operation as a backup during power failures or electrical faults. Meanwhile, the mechanical self-locking mechanism helps maintain the selected height after lifting. With its compact structure, smooth operation, and flexible installation options, this 5-meter telescopic mast offers a practical mounting platform for emergency lighting, surveillance cameras, communication antennas, detection equipment, and environmental monitoring instruments.
2. Structural Composition
The 5m manual-electric telescopic mast mainly consists of a top mounting seat, spiral cable, telescopic column, cable compartment, control cabinet, and mounting base. Each component serves a specific function to ensure reliable lifting and convenient equipment integration.
2.1 Main Components
1. Top Mounting Seat
The top mounting seat provides a secure connection point for lighting fixtures, surveillance cameras, communication antennas, and other payload equipment. It also includes reserved cable outlet holes for convenient electrical connections.
2. Spiral Cable
The black spring-loaded spiral cable runs along the side of the mast and extends or retracts together with the telescopic sections. It provides power and control or signal transmission for top-mounted equipment. Furthermore, its flexible structure helps reduce cable tangling, excessive pulling, and external wear during lifting operations.
3. Telescopic Column
The multi-section telescopic column serves as the main lifting and load-bearing structure. Its fire-red baked-paint finish provides a distinctive appearance for emergency and outdoor applications.
4. Cable Compartment
The cable compartment sits around the upper-middle section of the mast and features a ventilation grille. It provides space for cable storage and helps organize the internal cable arrangement.
5. Control Cabinet
The lower square control cabinet houses the motor driver, travel limit switches, and manual/electric switching mechanism. It provides convenient access to the main electrical and operating components.
6. Mounting Base
The steel flange base includes pre-drilled anchor bolt holes for secure ground installation. Users can also adapt the mounting structure to meet vehicle-mounted or shelter-based installation requirements.
3. Working Principle and Main Features
3.1 Manual-Electric Dual Drive System
The mast uses an electric drive system for normal lifting and lowering operations. However, when the power supply fails or an electrical fault occurs, users can switch to the manual backup mechanism to operate the mast and retract it safely.
3.2 Synchronized Spiral Cable System
The integrated spiral cable expands and contracts together with the telescopic column. As a result, the system maintains organized cable routing and provides continuous electrical connections for top-mounted equipment while reducing the risk of cable tangling, pulling, and abrasion.
3.3 Mechanical Self-Locking Function
The lifting transmission system features a mechanical self-locking design that helps maintain the selected mast height after operation stops. This function reduces the risk of unintended downward movement and supports stable equipment positioning.
3.4 Travel Limit and Electrical Protection
The mast includes upper and lower travel limit switches to control its extension and retraction range. In addition, the electrical system provides overcurrent, undervoltage, and short-circuit protection to improve operational reliability.
3.5 Distinctive Fire-Red Finish
The fire-red polyester powder coating gives the mast a highly visible appearance, making it suitable for firefighting, emergency response, rescue operations, and outdoor applications. It also provides surface protection against general environmental exposure.
3.6 Flexible Installation Options
Users can secure the mast to a flat surface through its flange base. Furthermore, we can customize the mounting structure for vehicle-mounted systems, mobile shelters, and other specialized platforms according to project requirements.
4. Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | 5m Manual-Electric Integrated Spiral Cable Telescopic Mast (Fire Red) |
| Rated Extended Height | 5 m |
| Retracted Height | Approx. 1.6 m (Reference) |
| Drive Mode | Electric Drive + Manual Backup |
| Lifting Transmission | Electric Actuator / Screw Drive with Mechanical Self-Locking |
| Lifting Speed | Approx. 0.1–0.3 m/s (Reference) |
| Top Rated Load | Approx. 20 kg Static Load (Reference) |
| Mast Material | 6061-T6 Aluminum Alloy (Steel Tube Optional) |
| Surface Treatment | Fire-Red Polyester Powder Coating |
| Power Supply | DC 12V / 24V or AC 220V (Customized) |
| Spiral Cable | Multi-Core Spring Spiral Cable; Core Count and Wire Gauge Customized |
| Protection Rating | IP65 (Reference) |
| Operating Temperature | -30°C to +60°C (Reference) |
| Wind Resistance | Working State: ≤ Beaufort 8; Retracted/Transport State: ≥ Beaufort 11 (Reference) |
| Limit Protection | Upper and Lower Travel Limit Switches |
| Electrical Protection | Overcurrent, Undervoltage, and Short-Circuit Protection |
| Installation Method | Ground Flange Mounting; Vehicle-Mounted / Shelter Installation Optional |
| Overall Dimensions / Weight | Confirmed According to Final Configuration and Factory Inspection |
Technical Notes:
Except for the specified 5 m extended height, manual-electric integrated drive, and fire-red appearance, the values marked as reference represent typical parameters for similar products. Actual performance depends on the final product configuration, payload conditions, installation method, and operating environment.
We confirm the final specifications according to the purchase agreement, project requirements, and factory inspection report. We can also customize the mast to meet specific application needs.
The reference payload capacity requires verification against the equipment’s weight, center of gravity, mounting arrangement, and wind load. Similarly, the reference wind resistance and IP65 protection rating require confirmation through the final design and relevant testing.
5. Applications
Our 5m manual-electric integrated spiral cable telescopic mast supports a variety of emergency, industrial, and outdoor equipment installation requirements.
Typical applications include:
- Fire Emergency Lighting: Elevates emergency lights, floodlights, and searchlights at firefighting and rescue sites.
- Video Surveillance: Supports surveillance cameras, checkpoint monitoring systems, and image-capture equipment.
- Emergency Communications: Raises communication antennas, signal relay equipment, and wireless communication devices to improve signal coverage.
- Radar and Detection Systems: Provides an elevated mounting platform for radar units, detection instruments, and lightning early-warning equipment.
- Weather and Environmental Monitoring: Supports meteorological sensors and outdoor environmental monitoring instruments.
- Vehicle and Shelter Applications: Integrates with mobile command vehicles, emergency shelters, and other mobile support platforms.
- Outdoor Fixed Installations: Provides an elevated mounting solution for equipment that requires a stable installation point.
Whether users need emergency lighting, communication support, or outdoor monitoring, this telescopic mast offers a flexible solution for different equipment configurations.
6. Installation and Operating Instructions
For safe operation and reliable performance, follow these installation and operating guidelines:
1. Prepare a Stable Installation Foundation
Install the mast on a flat, firm foundation. Use anchor bolts through the pre-drilled base holes, or select a suitable welded or bolted connection according to the installation design.
2. Control Payload Position and Weight
Keep the center of gravity of the top-mounted equipment as close to the mast axis as possible. In addition, control the cantilever length and eccentric loading to avoid excessive bending stress or uneven structural forces.
3. Check Electrical Connections
Verify the correct wiring polarity and phase connections according to the selected power supply. Ensure proper electrical grounding before operation.
4. Perform an Initial Test Run
Before the first lifting operation, run the mast without a payload to check the lifting direction, operating controls, and upper and lower limit switches. Confirm that all functions work correctly before installing the top equipment.
5. Follow Weather Safety Requirements
Retract the mast during strong winds, thunderstorms, and other severe weather conditions. Never exceed the rated payload or allowable eccentric loading limits.
6. Use Manual Backup Correctly
Use the manual backup mechanism only when the electric drive fails or the power supply becomes unavailable. After completing manual operation, return the manual components to their designated positions before resuming normal electric operation.
Important: Always check the mast, mounting base, electrical connections, and top-mounted equipment before operation. Follow the approved project-specific operating procedures and safety limits.
7. Maintenance and Care
Regular maintenance helps extend the service life of the telescopic mast and maintain reliable operating performance.
1. Inspect Fasteners and Cable Connections
Periodically check all mounting bolts, fasteners, electrical connectors, and cable connections. Inspect the spiral cable for cracks, aging, deformation, or other visible damage.
2. Lubricate Moving Components
Apply suitable grease to the transmission and sliding components according to the maintenance schedule. Keep the telescopic sections clean and prevent dust, sand, and other debris from entering the sliding surfaces.
3. Protect the Mast During Long-Term Storage
Retract the mast completely when the equipment remains unused for an extended period. Protect the unit from moisture, dust, and other environmental exposure, and store it in a dry, well-ventilated area.
4. Check Electrical and Mechanical Functions
Regularly test the electric drive, manual backup mechanism, travel limit switches, and electrical protection functions. Address any abnormal noise, movement, or electrical fault before further operation.
8. Ordering Information and Customization
To help us select the appropriate configuration and confirm the technical specifications, please provide the following information when placing an order:
- Top-Mounted Equipment: Equipment name, weight, and overall dimensions.
- Payload Center of Gravity: Position of the equipment’s center of gravity relative to the mast axis.
- Power Supply Requirements: Required voltage, current, and number of spiral cable cores.
- Installation Method: Ground flange mounting, vehicle-mounted installation, or shelter integration.
- Operating Environment: Design wind speed, ambient temperature, and corrosion exposure level.
- Additional Requirements: Special mounting adapters, cable connectors, control functions, and other customized accessories.
We can customize the mast structure, electrical configuration, spiral cable specifications, and mounting components according to your project requirements.
If the specifications in this product manual differ from those in the signed technical agreement, the agreed project specifications and factory inspection documents take precedence.
Contact us today to discuss your application and get a customized 5m telescopic mast solution.